All load banks in the hire fleet have been designed and manufactured by Hillstone using our extensive knowledge and experiance of battery, UPS & genset testing. Operating from rental depots in UK & UAE we strive to ensure our hire service is always delivered to the highest standards and according to our ISO9001:2008 quality assurance policy.Our load bank hire service includes: delivery, collection, installation, cable laying and equipment operation. Our principals and goals are to ensure the completion of the testing leaves the customer 100% satisfied and hopefully using Hillstone again in the near future.
![]() |
AC RENTAL LOAD BANKS |
| AC Load banks | Voltage ( V ) | Power ( KW ) |
| Server simulator 19" rack mounted |
240V 1ph | 4KW & 6KW |
| Hand carry | 240V 1ph | 15KW & 33KW |
| On castor wheels |
208V 3ph | 160KW |
| Hand carry | 415V 3ph | 19KW & 30KW |
| Portable units | 415V 3ph | 40KW |
| On castor wheels | 415V 3ph | 100KW |
| On castor wheels | 415V 3ph | 200KW |
| On castor wheels | 415V 3ph | 300KW |
| On UK road trailer | 415V 3ph | 500KW |
| On castor wheels | 415V 3ph | 650KW |
| On UK road trailer | 415V 3ph | 1000KW |
| DC RENTAL LOAD BANKS |
| DC Load banks | Voltage ( V ) | Rating | |
| Automatic control | 12V to 260V | 13KW | |
| Automatic control | 12V to 60V | up to 150A | |
| Hand carry | 12V to 30V | up to 600A | |
| Hand carry | 12V to 60V | up to 600A | |
| Dual Voltage | 60V to 120V | 18KW | |
| Hand carry | 110V to 140V | up to 430A | |
| Dual Voltage | 130V to 260V | 57KW | |
| On castor wheels | 260V | up to 300A | |
| Hand carry | 260V | 30KW | |
| Hand carry | 450V | 30KW | |
| On castor wheels | 480V | up to 375A | |
| Hand carry | 600V | up to 55A |
Regular load bank testing of generators provides an essential health check service to prevent diesel engine failure due to wet stacking. Wet stacking occurs due to under loading of the genset which results in wet un-burned fuel building up in the engine. This fuel build up will over time line the combustion chamber cylinders and cause a reduction of the engines rating and efficiency which will ultimately cause premature failure of the generator. Running the generator on load of 50% - 100% of the genset rating will allow the engine to reach the recommend operating temperature, which will burn off the choke deposits. Hillstone and our partners can provide preventive maintenance programs upon request.
Discharge testing is the approved method to determine the capacity of Lead acid and (Nickel Cadmium) Ni Cad/Ni Cd batteries, as recommended by all battery manufacturers such as Enersys, Exide, C&D Technologies, Hawker, Yuasa, Exide, Hoppecke, Saft, Varta, and in accordance to BS6290 part 4 / IEC TR 62060.
Legal Notice: Information published is for the public domain and permission is given to view and download datasheets and other product information at our discretion. All information published remains the intellectual property rights of Hillstone Products Limited as protected under the laws and jurisdiction of the United Kingdom. You are forbidden to copy, reproduce any designs for commercial gain without prior written agreement by Hillstone Products Limited. Information is given in good faith and accurate at the time of publishing.